Для правильного підбору насадки слід скористатися нижченаведеною таблицею:

DØ [мм]робочий тиск [бар]
100110120130140150160175200225250300400
021,004,54,74,85,05,35,35,65,96,36,77,07,78,9
0251,105,65,96,16,46,696,97,17,58,08,59,09,911,4
031,186,87,17,47,78,08,38,69,09,610,210,711,813,6
0351,307,88,28,68,99,29,59,810,311,011,712,313,815,5
041,359,49,810,310,711,111,511,912,413,314,114,816,318,7
0451,4010,210,510,911,411,812,212,613,214,115,015,817,419,9
051,5511,311,812,412,913,413,814,314,916,016,917,919,722,6
0551,6012,413,013,614,114,715,215,716,417.518,619,621,725,0
061,7213,614,314,915,516,016,717,218,019,220,421,523,727,1
0651,7514,715,416,116,817,418,018,619,420,822,023,225,629,3
071,8015,816,617,318,018,719,320,020,922,323,725,027,131,3
0751,9016,917,718,519,320,020,721,422,423,925,326,729,433,7
082,0518,018,919,720,521,322,022,823,825,527,028,531,435,9
0852,0819,120,020,921,822,623,424,125,327,028,630,234,539,8
092,1020,221,222,123,023,924,725,526,728,630,331,935,140,2
102,3022,523,624,625,626,627,628,529,831,833,735,639,544,9

Подальші кроки до вибору калібрування (позначення відповідного діаметра виходу насадки):

  1. З таблички з номерами пристрою мийки слід зчитати робочий тиск та витрату пристрою (наприклад, 200 бар і 18 л/хв).
  2. В таблиці знаходимо відповідне значення тиску (200 бар) і в колонці «200» шукаємо рядок з найближчим значенням витрати, тобто 17,5. Увага: якщо витрата вказана в інших одиницях, її слід перевести в [л/хв].
  3. Від поля «17,5» переходимо вліво до колонки «D», де читаємо значення калібрування – 055.